Wire loop - not recognised by table

gabrielferaru

New member
Hi!


I have a simple harness: one connector and one wire loop on this connector.








The wire named 555 looks ok on harnessassembly. The wire starts on pin 2 and ends on pin 5.








But, on harness drawing, on my "wire table" the 555-wire is reported wrong. The both ends for this wire are on the pin 2.








Where is the mistake?
 
THAT IS A BUG.


IT IS RESOLVED IN WILDFIRE 2.0 DATECODE M240 OR LATER








Solution


















134084

Type
TAN

Created Date
29-Aug-2006

Last Updated
29-Aug-2006



Title
If wires/­cables are routed between different pins of the same connector, report tables display incorrect route information, i.­e.­ the same pin name is displayed for both ends (­from and to)­.­

Details

Description



If wires/cables are routed between different pins of the same connector, report tables display incorrect route information, i.e. the same pin name is displayed for both ends (from and to).
Resolution



This issue will be resolved in a future version of Pro/ENGINEER.
Affected Products



Product
Pro/ENGINEER

Module
CABLE

Reported Release
Wildfire 2.0

Reported Datecode
M190

Resolved Release
Wildfire 2.0

Resolved Datecode
M240

Affected Client
All

Affected Server
Not Available
 

Sponsor

Articles From 3DCAD World